產品展示 ·  Product list
      Location:Home>Product List>CROSBY A-345
      CROSBY A-345
      Introduction

      A-345 Master Link Assembly

      Size  Stock No. Weight Each  Working Load Limit Based on 5:1 Design Factor* Proof Load ** Dimensions (mm) Deformation Indicator
      (mm) (in.) (kg)  (t) (KN) A B C D E F G
      19W 3/4W 1014739 1.59 5.6 126 19 81.3 152 14.2 85.1 45 7.62 102
      22W 7/8W 1014742 2.18 6.9 157 22 95.3 162 14.2 85.1 45 7.62 114
      26W 1W 1014766 4.22 11.8 267 26 109 191 19.1 100 59.9 8.38 140
      32W 1-1/4W 1014779 7.17 17.7 402 32 140 241 25.4 160 89.9 13 178
      † 32W † 1-1/4W 126260 12.5 † 16.4 403 32 111 222 32 222 111 - 140
      38W 1-1/2W 1014807 15.47 27.7 628 38 150 267 31.8 180 100 16.5 191
      † 38W † 1-1/2W 1262612 21.6 † 24.6 604 38 133 267 38 267 133 - 160
      44 1-3/4 1014814 20.9 38.5 944 44 152 305 35.1 203 127 18.5 191
      † 44 † 1-3/4 1262621 33.7 † 38.5 944 44 152 305 44 305 152 - 191
      51 2 1014832 30.4 46.5 1141 51 178 356 38.1 229 146 - 229
      † 51 † 2 1262630 51.3 † 46.5 1141 51 178 356 51 356 178 - 229
      64 2-1/2 1014855 93.4 72.6 1423 64 213 406 63.5 406 213 - 279
      70 2-3/4 1014864 128 98.4 1929 70 251 457 69.9 457 251 - 318
      102 4 1014999 303 169 3319 102 305 610 89 610 305 - 394***
      * Ultimate Load is 5 times the Working Load Limit. The maximum individual sublink working load limit is 75% of the assembly working load limit except for 2-1/2”and 2-3/4”, which are 100% of assembly working load limit. Applications with wire rope and synthetic sling generally require a design factor of 5. **Proof Test Load equals or exceeds the requirement of ASTM A952(8.1) and ASME B30.9. †Ultimate Load is 4 times the Working Load Limit for Offshore Container Master Links. †Offshore Container Master Links Proof Tested to 2.5 times the Working Load Limit with 70 percent fixtures. †† Welded Master Link.